Á¦Ç°¼Ò°³
¤ýÀÚ¼¼ÃøÁ¤ÀåÄ¡, IMU, GPS/INS
¤ý°í¼º´É MEMS °ü¼º ¼¾¼­, ½Ã½ºÅÛ ¹× ÅëÇÕ GPS
¤ý°íÃâ·Â ¹«¼± ÁõÆø±â
¤ýGNSS ½Ã¹Ä·¹ÀÌÅÍ, GNSS Test & Software Receiver
¤ýIP Core Á¦Ç°
¤ýÅë½ÅÄÉÀ̺í Æ÷¼³Àåºñ
¤ý½Ç³» À§Ä¡(ÃøÀ§) ÃßÀû ½Ã½ºÅÛ
¤ý¹«¼± µ¥ÀÌÅÍ Àü¼Û ½Ã½ºÅÛ
¤ý¼ö¼Ò ¸ÞÀÌÀú, ¼ö¼Ò ½Ã°è
Product Overall
Active Hydrogen Frequency Standard VCH-1003A
Active Hydrogen Maser VCH-1003M
Active Hydrogen Frequency Standard VCH-1005
Passive Hydrogen Maser VCH-1008 new (in development)
¤ýGPS ½Ã°¢µ¿±âÈ­ Àåºñ
¤ýÃÊÁ¤¹Ð ½Ã°£ ÁÖÆļö Àåºñ
¤ý´ÙÁ߸ðµå¿ë Telemetry ¼Û/¼ö½Å±â
¤ýFilter Connector
  Global Partners
Exclusive Representative Contract
with Global Companies
¼ö¼Ò ¸ÞÀÌÀú, ¼ö¼Ò ½Ã°è > Active Hydrogen Maser VCH-1003M
 
Active Hydrogen Maser VCH-1003M
The VCH-1003M is a state-of-the-art, high-performance maser with low phase noise option. It utilizes the latest maser technologies, including Stand-alone Auto Cavity Tuning (no external reference required), remote IP control, monitoring and self-diagnostics.
Key Applications
  • National Time Keeping Service;
  • Deep space tracking and navigation
  • VLBI
  • GNSS satellite monitoring
Specifications
Output signals
  • Sine: two outputs 5 MHz (sine), 1 ¡¾ 0.2 V RMS into 50 Ohms,
  • two outputs 10 MHz (sine), 1 ¡¾ 0.2 V RMS into 50 Ohms,
  • two outputs 100 MHz (sine), 1 ¡¾ 0.2 V RMS into 50 Ohms,
  • one output 1400 MHz (option)
  • Pulse: two outputs 1 Hz (pps); Amplitude: > 2.5 V into 50 Ohm ; Width: 10-20 ¥ìs ; Rise time: <3 ns
Standard Option L
3 Hz 3 Hz 0.5 Hz
Frequency stability (Allan deviation) 1 s

¡Â1.5¡¿10e-13

8.0¡¿10e-14

6.0¡¿10e-14

10 s

¡Â2.5¡¿10e-14

1.4¡¿10e-14

1.3¡¿10e-14

100 s

¡Â6¡¿10e-15

4.0¡¿10e-14

3.6¡¿10e-14

1000 s*

¡Â2¡¿10e-15

1.5¡¿10e-15

1.3¡¿10e-15

3600 s*

¡Â 1.5¡¿10e-15

1.5¡¿10e-15

1.0¡¿10e-15

1 day*

¡Â7¡¿10e-15

5.0¡¿10e-16

5.0¡¿10e-16

Long term: ** <3.0e-16 per day
Synthesized Frequency Resolution
Frequency control range
1¡¿10e-16
1¡¿10e-10
Harmonic distortion:
Non-harmonic distortion:
< 30 dB (for 5 MHz output)
< -100 dB in the range from 10 Hz to 10 kHz
Temperature sensitivity ¡Â 2¡¿10e-15 / C¡Æ
Magnetic sensitivity ¡Â 1¡¿10e-14 / Gauss
Phase noise (dBc/Hz) offset standard Option L
1 Hz -118 -130
10 Hz -135 -142
100 Hz -149 -152
1000 Hz -156 -156
* Specified only under laboratory conditions: at ¡¾1 ¡ÆC ambient temperature change in 10-35 ¡ÆC operating temperature range.
** Achieved after extended period of unperturbed, continuous operation.
Manual synchronization to external 1 pps TTL signal with 50 ns accuracy.
Operating temperature range: +5 C¡Æ to +35 C¡Æ
Power: 85 to 264V, 50 Hz; 22-30V dc
Power consumption: 150 VA ac, 100 W dc
Dimensions (WxHxD): 550 mm ¡¿ 990 mm ¡¿ 550 mm
Weight: 105 kg
Full data monitoring and functions control (local or remote through any network) performs by personal computer
Application software runs under Microsoft WindowsTM
Lifetime: 15 years