The 9.192 GHz Synthesizer CS-1 constitutes of two separate units: the Synthesizer Module and the DC Module.

The Synthesizer Module is a high stability and high resolution signal source designed to be used in the implementation of a Cesium atomic clock. The unit is provided in a 2U, 19 inch rack-mount enclosure. All synthesizer functions are accessed from the front panel or a RS232 interface. An external trigger input may be used to synchronize programmable events such as frequency sweeps, phase modulation and amplitude modulation with external events.

The synthesizer is implemented with a flexible modular topology. Two ultra-low noise quartz oscillators are part of the multiplication chain from 5 MHz to 100 MHz. Buffered outputs are provided at the front panel for 5 MHz, 10 MHz and 100 MHz. The 100 MHz signal is the highest frequency in the low frequency section of the synthesizer. This 100 MHz signal is distributed using a 1 input, four output isolation amplifier. One of these 100 MHz signal is used as the reference for a 9.2 GHz DRO. The output of the 9.2 GHz DRO is buffered and used to drive the LO port of a single-sideband mixer. The second 100 MHz signal is used to clock a DDS synthesizer module. The DDS synthesizer generates a 7.xx MHz signal with 48 bit resolution and complete modulation capabilities. The DDS synthesizer output drives the IF port of the single-sideband mixer. The lower sideband of the mixer is selected as the output generating the 9.192 GHz output signal. The amplitude of the 9.192 GHz output is controlled with 12 bits of resolution and an internal relay may be used to turn off the RF signal.

The DC Module, also in a 2U, 19-inch rack-mount enclosure, provides the DC power to the Synthesizer Module through DC cable.


Request a quote for this item.
Specification
Parameter
Conditions
Typ
Units
Frequency Stability
Ref. 5MHz, +13 dBm
Pair Measurement
Averaging Time
1 s
10 s
100 s
1000 s
100000 s
1000000 s
-
6x10-14
6x10-15
6x10-16
7x10-17
3x10-17
1x10-17
 
Phase Noise
Carrier 9.192 GHz
Pair Measurement
Offset Frequency
1 Hz
10 Hz
100 Hz
1kHz
-
-69
-80
-93
-107
dBc/Hz
Phase Noise
Carrier 100 MHz
Offset Frequency
10 Hz
100 Hz
1 kz
> 10kHz
-
-120
-133
-155
-175
dBc/Hz
Phase Noise
Carrier 10 MHz
Offset Frequency
1 Hz
10 Hz
100 Hz
> 1kHz
-
-114
-142
-160
-168
dBc/Hz
Phase Noise
Carrier 5 MHz
Offset Frequency
1 Hz
10 Hz
100 Hz
> 1kHz
-
-118
-150
-167
-17
dBc/Hz
Temperature Coefficient @ 9.192 GHz   0.5 ps/K